Engineering · Service contract
Technical expertise for helipad construction on Building D
Technical testing, analysis and expert assessment of the structural condition of Building D to support the planned construction of an elevated helipad for emergency helicopters at the hospital.
- Deadline
- Closed 29 days ago
- Location
- Toruń, Kujawsko-Pomorskie, Poland
About the project
Technical testing, analysis and expert assessment of the structural condition of Building D to support the planned construction of an elevated helipad for emergency helicopters at the hospital.
Scope of work
Execution of technical testing, structural analysis and expert assessment of Building D to determine its suitability for the planned construction of an elevated helipad for emergency helicopters. The service includes engineering studies, structural load capacity evaluation and technical consultation.
Deliverables
- Technical expertise report on the structural condition of Building D
- Engineering studies and structural analysis
- Assessment of load-bearing capacity for helipad construction
Required services
- Technical testing and analysis
- Structural engineering consultation
- Expert assessment of building construction
- Post-expertise consultation
Pelenoir assessment
This project is primarily an engineering-focused initiative to assess the structural feasibility of constructing an elevated helipad on an existing hospital building. The scope centers on technical testing, structural analysis, and expert evaluation of load-bearing capacity, with secondary advisory services to support decision-making.
-
Engineering 90%
Structural engineering analysis, load-bearing capacity assessment, and technical expertise to evaluate the suitability of Building D for the planned elevated helipad construction.
-
Post-expertise consultation and advisory services to interpret the structural assessment results and guide next steps for helipad construction.
How to take part
Who can apply
- Proven execution of at least two similar technical expertise services for reinforced concrete, steel or mixed-structure buildings with a minimum volume of 1,000 m³ or height exceeding four storeys within the last three years
What to submit
- Offer prepared in Polish
- Completed Appendix 1 to the Terms of Reference (SWZ) as the detailed description of the subject matter
- Appendix 5 (declaration of non-exclusion under Art. 125(1) of the Public Procurement Law)
- Appendix 6 (list of executed services with references)
- Electronic submission via the Marketplanet Procurement Platform
Award criteria
- Price (60% weight)
- Additional consultations after expertise delivery (40% weight)
Source
Published on e-Zamowienia. Original title: Wykonanie badań i ekspertyzy technicznej konstrukcji budynku D na potrzeby planowanej budowy wyniesionego lądowiska dla śmigłowców ratunkowych.
Summary and assessment prepared by Pelenoir from the public notice (25 Oct 2026). The original notice and its documents are binding. Page updated 22 Oct 2026.
Pelenoir PAL
Find the tenders that fit your practice.
PAL reads every public notice and ranks the opportunities that match your portfolio, team and ambitions.