Engineering · Service contract
Tresna Dam Anti-Seepage Curtain Documentation and Testing
Preparation of execution documentation for sealing the anti-filtration curtain under sections 9 and 10 of the inspection-injection gallery of the Tresna Dam, including water absorption testing and trial cementation.
- Deadline
- Closed 46 days ago
- Location
- Czernichów, Śląskie, Poland
About the project
Preparation of execution documentation for sealing the anti-filtration curtain under sections 9 and 10 of the inspection-injection gallery of the Tresna Dam, including water absorption testing and trial cementation. The project aims to restore the dam to proper technical condition and is classified as a Class I hydrotechnical structure.
Scope of work
Preparation of execution documentation for sealing the anti-filtration curtain of the Tresna Dam, including water absorption testing and trial cementation. The project requires specialized engineering services for hydrotechnical structures and compliance with technical standards for dam safety.
Deliverables
- Execution project documentation for anti-filtration curtain sealing
- Water absorption testing report
- Trial cementation report
Required services
- Civil engineering design for hydrotechnical structures
- Geotechnical testing and analysis
- Cementation and injection works planning
Pelenoir assessment
This project is primarily focused on engineering and technical planning for hydrotechnical infrastructure, specifically the design and testing of an anti-filtration curtain for a Class I dam. The scope includes civil engineering design, geotechnical testing, and cementation planning, with secondary involvement of geomatics and surveying for subsoil analysis and measurement.
-
Engineering 80%
Preparation of execution documentation for the anti-filtration curtain sealing, including structural and technical engineering design for hydrotechnical infrastructure. This includes planning for water absorption testing and trial cementation to ensure dam safety and compliance with Class I hydrotechnical structure standards.
-
Surveying 20%
Geotechnical surveying and analysis, including water absorption testing and assessment of the dam's subsoil conditions to support the design of the anti-filtration curtain. This involves precise measurement and mapping of geological parameters for hydrotechnical engineering.
How to take part
Who can apply
- Experience in preparing documentation for anti-filtration curtains using zonal injection methods on Class II or higher hydrotechnical structures
- Minimum two personnel with valid construction licenses in hydrotechnical engineering (designer and verifier)
- Minimum one geologist with Category VII or equivalent geological license and experience in zonal anti-filtration curtains
What to submit
- Completed offer form (Załącznik Nr 1 do SWZ)
- Power of attorney (if applicable)
- Statements on exclusion criteria and compliance with participation conditions (Załączniki Nr 6, 7, 8, 9, 10, 11)
- List of completed services (Załącznik Nr 4)
- List of personnel (Załącznik Nr 5)
- Documents confirming wadium (bid bond) payment or guarantee
Award criteria
- Gross price (80% weight)
- Warranty period (20% weight, minimum 36 months, maximum 76 months)
Source
Published on e-Zamowienia. Original title: Wykonanie dokumentacji wraz z badaniem wodochłoności i próbnej cementacji na doszczelnienie przesłony przeciwfiltracyjnej Zapory Tresna w sekcji G10.
Summary and assessment prepared by Pelenoir from the public notice (8 Oct 2026). The original notice and its documents are binding. Page updated 29 Sep 2026.